Filter Results By:

Products

Applications

Manufacturers

Data Acquisition Systems

sense, log and store information. AKA: DAS

See Also: Data Acquisition, PCI Data Acquisition, DAQ


Showing results: 661 - 675 of 853 items found.

  • VME – NIM Power Supplies

    CAEN S.p.A.

    VME solutions are an integral part of CAEN’s design history. CAEN VME solutions for Data Acquisition and Front End applications have been part of were first developed decades ago. These solutions have been upgraded and modernized multiple times, and were recently joined by CAEN VME programmable High Voltage Boards. Thanks to the innovative GECO2020 Control Software, and the multi-master capability of CAEN VME Bridges, it is now possible to accommodate and independently control an integrated VME DAQ/HV System.

  • Temperature Sensors

    TT420 - Electro-Sensors, Inc.

    Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)

  • Temperature Sensor

    ITS-7025 - Innovative Technical Systems

    The ITS-7025 Temperature Sensor was developed to monitor the temperature of liquid-cooled klystron amplifiers. The sensor is designed to clamp directly to the cooling pipe and provide an analog voltage output from 0 to 10 VDC corresponding to 0 to 100 degC with 2 degC accuracy. Two analog outputs are provided; one for connection to a remote data acquisition system, and a second for local service monitoring. A single +28 VDC (other voltages available) powers the sensor which draws less than 100 uA.

  • Remote Spectral Detector

    CSS-45 - Gigahertz-Optik GmbH

    The CSS-45 detector incorporates a powerful microprocessor which performs not only data acquisition but also all necessary lighting calculations. Both USB 2.0 and RS 485 interfaces are standard enabling the flexible configuration of single and multi-detector based systems. An optional software development kit supports integration into third party application software. With its wide spectral range from 360 nm to 830 nm the CSS-45 is ideal, for example, as a high accuracy photometric and colorimetric detector (according to CIE S023).

  • PXI High Density MUX 47-Channel 2-Pole

    40-640-022-47/2 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector. It may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available for this 1-pole version).

  • PXI High Density MUX 94-Channel 1-Pole

    40-640-022-94/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The multiplexer module is available as a 47-channel 2-pole, 94-channel 1-pole or 47-channel 1-pole with screened relays. Connections are made via a front panel 96-pin connector. It may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available for this 1-pole version).

  • 224 Channel Digital I/O Modular PXI Card

    GX5731 - Marvin Test Solutions, Inc.

    The GX5731 is a 6U modular digital I/O card with 224 I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5731 offers the highest density in the industry for a single PXI plug-in board. Of the 224 channels, 128 support TTL levels with the direction of each group of eight channels programmable as input or output. The other 96 channels can be used for customized I/O using MTS' GX57xx series I/O modules.

  • 224 Channel Digital I/O Modular PXI Card

    GX5731 - Terotest Systems Ltd.

    The GX5731 is a 6U modular digital I/O card with 224 I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5731 offers the highest density in the industry for a single PXI plug-in board. Of the 224 channels, 128 support TTL levels with the direction of each group of eight channels programmable as input or output. The other 96 channels can be used for customized I/O using MTS' GX57xx series I/O modules.

  • Partial Discharge Expert Diagnostic and Location System

    PDExpert - Power Monitoring and Diagnostic Technology Ltd.

    The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.

  • Curved Needle Test Systems

    Instron

    The Instron® Curved Needle Testing System is built on the 5900 system platform and is ideally suited for needles used in abdominal, fistula, vascular, intestinal, or other surgical procedures. This system provides two different needle testing solutions: one for curved needle puncture testing and one for bend testing. The curved needle puncture testing fixture is used to evaluate needle sharpness and insertion force, while the needle bend testing fixture is used to evaluate flexural properties of the needle during use. With its tabletop design, the Curved Needle Testing System has a small footprint and takes up minimal bench-top space. The testing system operates with Instron Bluehill® Universal software that provides test control, data acquisition, test results, and reports, as well as a large library of calculations.

  • USB Data Acquisition (DAQ) Products

    Acces I/O Products, Inc.

    ACCES now offers USB-based data acquisition and control in both standard packaging and embedded OEM USB/104 board only options. These USB DAQ devices are perfect for a variety of applications requiring monitoring, control and industrial serial communications. USB is by far the most popular and compatible standard data interface for direct PC connection. Add the features you need in your application in hours, not days. Choose from over 100 different models and options (including extended temperature) encompassing analog I/O, digital I/O, counter/timer, and serial I/O configurations. Experience simple and immediate connection to any PC or embedded system with a USB port.

  • DataNet Wireless Data Loggers

    Fourier Systems

    The DataNet wireless system is a data acquisition solution developed for 24/7 real-time monitoring for mission critical organizations. Boasting a variety of wireless data logger models using ZigBee RF technology, the DataNet solution is capable of measuring parameters such as temperature, relative humidity, voltage, current, or frequency. Choose from DataNet models offering up to 6 inputs or the more cost-effective single or dual input Mini DataNet range, depending on your application requirements. Each DataNet mesh network is managed by a Receiver connected via USB to a Windows-based PC, and also supports addition of wireless Repeater units for extending the network transmission range and improving network robustness.

  • PCI Data Acquisition Boards

    AD8-1500DMA Series - 8 bit, 1.56 GS/s - Ultraview Corporation

    The AD8-1500DMA series has a 1500 MSPS 8-bit A/D, 8GB/16GB of on-board SDRAM memory and the ability to transfer data directly into the computer system's memory at up to 320 MB/s on 64-bit PCI systems. Sampling is controlled by an onboard oscillator or by an external clock input, which may be in the frequency range between 20 MHz and 1500 MHz. Multiple boards may be configured to acquire either concurrently, for more simultaneous acquisition channels, or sequentially, with an automatic overlap selectable from 0 to nearly 2GB, in 512KB steps, for longer record length. Drivers for 64 bit Linux and Solaris operating systems included.

  • PXI Single 44 x 4 Matrix 1 Pole Screened

    40-523-021-S - Pickering Interfaces Ltd.

    The 40-523 module is configured as a 44x4 high density matrix with available reedrelay formats of 1-pole, 2-pole and 1-pole screened. The screened version is suitablefor switching signals up to 50MHz. Model 40-524 is a similar matrix, available insingle pole 46x4 format. Typical applications include signal routing in FunctionalATE and data acquisition systems. These PXI matrix cards are constructed using highreliability Ruthenium Electro-Plated Reed Relays, offering >10e8 operations togive maximum switching confidence with long life and stable contact resistance.

  • PXI Single 32x8 Matrix Card, 1 Pole

    40-530-021 - Pickering Interfaces Ltd.

    Typical applications for this high-density reed relay matrix include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.

Get Help